Page 410 - Saginaw_Medical_Custom_Medical Catalog
P. 410
BOVIE NEURO-PULSE A811 A830 A831 ES60R
This nerve locator/stimulator BOVIE REUSABLE ACTIVE ELECTRODES BOVIE REUSABLE NEEDLES ES62R
has three variable outputs
(1/2mA, 1mA, 2mA) which Packaged non-sterile and can be autoclaved for multiple uses. ES60R Needle, Super Fine 3cm, Reusable
allow the surgeon to select the correct current depending on The electrodes are designed with an industry-standard 3/32” ES62R Needle, Super Fine 4.5cm, Reusable, Non-Sterile
nerve size. The light emitting diode (LED) illuminates when shaft to fit most electrosurgical pencils.
the probe contacts exposed tissues. Excellent for hand and
reconstructive surgery. Sterile. Two-year shelf life. A811 Reusable Electrode CONMED ELECTROLASE®
0003 Neuro-Pulse, 10/bx A830 Sharp Electrode, Angled DISPOSABLE HYFRECATOR
A831 Ball Electrode, Short Angled TIPS
BOVIE RESISTICK A832M Electrode, 3/32” Ball, Reusable, Short Straight
II™ COATED BALL A833 Needle Electrode, Short Straight Electrolase tips are the inexpensive
ELECTRODES A834 Needle Electrode, Angled Fine solution to potential hazards of
A834T Needle Electrode, Angled Fine, Tungsten cross contamination and accidental needle sticks.
Resistick II™ coated blade, ball and needle electrodes are A836 Needle Electrode, Long Straight
expertly coated with PTFE(polytetrafluoroethylene). They move ES01R Electrode Blade, Standard, Non-Sterile, Reusable 7-100-12BX Sharp Tips Ideal For Pinpoint Coagulation
more effectively through tissue becausethey resist eschar ES02R Standard Needle, Reusable, Non-Sterile Procedures, Light Gray Plastic Base, Non-Sterile,
build-up making them much more efficient during surgical ES03R Extended Needle, Reusable, Non-Sterile 100/bx
procedures. Unlike the common stainless steel electrodes with ES04R Extended Blade, Reusable
a propensity to accumulate the discarded blood and tissue, ES06R Electrode, Extended 3mm Ball, Reusable, 7-100-8BX Sharp Tips Ideal For Pinpoint Coagulation
Resistick II™ coated electrodes simply wipe clean. Non-Sterile Procedures, Light Gray Plastic Base, Sterile, 50/bx
ES07R Electrode, Extended 5mm Ball, Reusable,
ES06T Ball Electrode, 5”, 3mm Dia, 12/bx Non-Sterile 7-101-12BX Blunt Tips Ideal For Broad Based Coagulation
ES07T Ball Electrode, 5”, 5mm Dia, 12/bx ES08R Electrode, 5mm x 5mm Loop, Reusable, Procedures, Dark Gray Plastic Base, Non-Sterile,
ES20T Ball Electrode, 2”, 5mm Dia, 12/bx Non-Sterile 100/bx
ES21T Ball Electrode, 2”, 4mm Dia, 12/bx ES09R Electrode, 10mm x 10mm Loop, Reusable,
ES50T Ball Electrode, 2”, 3mm Dia, 12/bx Non-Sterile 7-101-8BX Blunt Tips Ideal For Broad Based Coagulation
ES10R Electrode, 15mm x 8mm Loop, Reusable, Procedures, Dark Gray Plastic Base, Sterile, 50/bx
Non-Sterile
ES01T ES18T ES11R Electrode, 15mm x 10mm Loop, Reusable,
BOVIE RESISTICK II™ COATED BLADE Non-Sterile
ELECTRODES ES12R Electrode, 20mm x 8mm Loop, Reusable, 138004 711B
Resistick II™ coated blade, ball and needle electrodes are Non-Sterile
expertly coated with PTFE(polytetrafluoroethylene). They move ES13R Electrode, 20mm x 15mm Loop, Reusable, CONMED HYFRECATOR ELECTRODES
more effectively through tissue becausethey resist eschar Non-Sterile
SURGERY/MINOR build-up making them much more efficient during surgical ES14R Electrode, 5mm x 5mm Loop, Reusable, 138004 Reusable Electrode, 5/8” Needle, 2” Overall, 5/pk
PROCEDURE procedures. Unlike the common stainless steel electrodes with Non-Sterile 138018 Reusable Ball Electrode, 3/16”, 1.6” Overall, 10/pk
a propensity to accumulate the discarded blood and tissue, ES16R Electrode, 10mm x 8mm Square, Reusable, 138019 Reusable Ball Electrode, 1/8”, Short Shaft, 1 3/4”
Resistick II™ coated electrodes simply wipe clean.” Non-Sterile 705A Overall, 5/pk
ES18R Electrode Blade, Angled, Non-Sterile, Reusable Reusable Electrode, Dental/ Vasectomy Needle,
ES01T Blade Electrode, 2 3/4”, 12/bx ES20R Electrode, 3/16” Ball, Reusable, Non-Sterile 711B 75° Angled, 1/2” Fine-Wire Electrode, Overall
ES04T Blade Electrode, 6”, 12/bx ES21R Electrode, 5/32” Ball, Reusable, Non-Sterile 714 2 3/4”
ES18T Angled Blade Electrode, 2 3/4”, 45°, 12/bx ES23R Electrode, 5/16 Short Shaft Loop, Reusable, General Purpose Electrode, 45° Angled, 7/8”
ES37T Blade Electrode, Extended Insulation, 2 3/4”, Non-Sterile 716 Electrode, Overall 3”
12/bx ES31R Electrode, 20mm x 20mm Loop, Reusable, Epilation/ Telangiectasias Needle Set, 30° Angled,
ES39T Blade Electrode, Extended Insulation, 6”, 12/bx Non-Sterile 3/8” Extra Fine Tungsten Needle Electrodes For
ES54T Blade Electrode, Extended Insulation, 4”, 12/bx ES42R Electrode, 20mm x 12mm Loop, Reusable, Precise Procedures, Overall 1 3/4”, 6/pk
ES55T Blade Electrode, 4”, 12/bx Non-Sterile Long Desiccation Needle, 3/8” Needle Electrode On
ES58T Blade Electrode, 2 1/2”, 12/bx ES43R Electrode, 15mm x 15mm Loop, Reusable, Long Shaft, Overall 5”
ES59T Blade Electrode, Extended Insulation, 2 1/2”, Non-Sterile
12/bx ES44R Electrode, 15mm x 5mm Loop, Reusable, COVIDIEN/ENERGY-BASED DEVICES VALLEYLAB
Non-Sterile EDGE™ COATED ELECTRODES
BOVIE RESISTICK ES45R Electrode, 13mm x 13mm Loop, Reusable,
II™ COATED NEEDLE Non-Sterile High performance cutting and coagulation with easy cleaning.
ELECTRODES ES46R Electrode, 10mm x 5mm Loop, Reusable, Standard 0.24cm (3/32 inch) diameter shaft. Provides
Non-Sterile uncompromised cut performance throughout a variety of
Resistick II™ coated blade, ball and needle electrodes are ES47R Electrode, 25mm x 10mm Loop, Reusable, procedures, no matter what type of tissue. EDGE™ coated
expertly coated with PTFE(polytetrafluoroethylene). They move Non-Sterile blade and coated needle electrodes provide cut performance
more effectively through tissue becausethey resist eschar ES49R Electrode, 20mm x 10mm Loop, Reusable, like stainless steel, but with a clean advantage. No scraping
build-up making them much more efficient during surgical Non-Sterile required. Durable and bendable without compromising the
procedures. Unlike the common stainless steel electrodes with ES51R Electrode, 13mm x 8mm Loop, Reusable, integrity of the coating.
a propensity to accumulate the discarded blood and tissue, Non-Sterile
Resistick II™ coated electrodes simply wipe clean. ES52R Electrode, 10mm x 8mm Loop, Reusable, E1450G Coated Blade Electrode, 7.62cm (3.0 in.), For All
Non-Sterile E1450X Non Hex-Locking Pencils, 50/cs
ES53R Electrode, 15mm x 12mm Loop, Reusable, Coated Blade Electrode, 6.35cm (2 1/2”), For All
Non-Sterile Valleylab Hex-Locking Pencils, 50/cs
ES02T Needle Electrode, 2 3/4”, 12/bx HALYARD RADIOFREQUENCY ACCESSORIES
ES03T Needle Electrode, 6”, 12/bx
ES38T Needle Electrode, Extended Insulation, 2 3/4”, Accessories for radiofrequency generators, probes and
12/bx cannula for the solutions to chronic spinal pain.
ES40T Needle Electrode, Extended Insulation, 6”, 12/bx
ES56T Needle Electrode, 4”, 12/bx PMA-GP-BAY Grounding Pad with Cord
ES57T Needle Electrode, Extended Insulation, 4”, 12/bx PMF18-100-10CS Cannula, Radiopaque Marker, 18G, 100mm
Length, 10mm Active Tip, Curved Sharp,
Sterile Individually Packaged, 10/cs
376 Electrosurgery