Page 209 - Saginaw_Medical_Custom_Medical Catalog
P. 209
COVIDIEN/MEDICAL ARKRAY TECHLITE® LANCETS HTL-STREFA DROPLET® LANCET
SUPPLIES INFANT HEEL
WARMER Sterile, disposable devices used to obtain
a capillary blood sample. Compatible
Provides a fast, safe, and with most standard lancing devices.
economical means to apply The lower gauge lancets work best on
just the right amount of heat callused fingers where it is sometimes
to infant’s heel for blood difficult to obtain a sample. The higher
sampling. Simply squeeze the gauge lancets work best for individuals that lance their finger
pouch for instant activation. frequently or have thin skin (such as a child or elderly person).
Heel warmer quickly reaches
the proper temperature and 880125 Lancet, 25G, 100/bx 7105 Droplet Lancet, 28G, Blue, 200/bx, 10 bx/cs LAB EQUIPMENT
maintains this temperature for several minutes. MH00002T 880128 Lancet, 28G, 100/bx 7106 Droplet Lancet, 28G, Blue, 100/bx, 10 bx/cs & ACCESSORIES
has an adhesive tab for convenient attachment to the infant. 880225 Lancet, 25G, 200/bx 7161 Droplet Lancet, 30G, Purple, 100/bx, 10 bx/cs
7162 Droplet Lancet, 30G, Purple, 200/bx, 10 bx/cs
MH00002N No Adhesive Attachment Pad, 100/cs BD MICROTAINER® CONTACT- 9000 Droplet Lancing Device, 50/bx
MH00002T Adhesive Attachment Pad, 100/cs ACTIVATED LANCETS 9000-1 Droplet Lancing Device, 400/bx
SIMPORT BLOOD BD MICROTAINER® Contact-Activated HTL-STREFA MEDLANCE®
DILUTION VIALS Lancet has been designed with a PLUS EXTRA
positive patent experience in mind. The contact activation
Made of polystyrene. Optically method facilitates a consistent puncture depth and minimizes Medlance Plus Extra is your capillary
clear parallel sides, deionized the likelihood of having to repeat the puncture. It covers blood sampling solution when your
and destaticized. The snap cap only a small area at the contact point, resulting in improved patient has tough or calloused hands - or
is leakproof but easily removed. visibility of the puncture site for the clinician and greater when you just need a larger sample.
Guaranteed to meet or exceed accuracy of the lancet positioning when performing the Features include: (1) Intuitive two step
O.E.M. specifications. Each lot is tested to ensure cleanliness. puncture. Its’ innovative ergonomic design allows for a more operation and contact activation; (2)
comfortable grip. The lancet automatically retracts into the Improve patient comfort with silicone coated needles; (3)
V130 25mL Sample Dilution Vial, 50/tray, 20 trays/cs device, which prevents the lancet from being reused. In Increase safety using a double spring mechanism to ensure
V130-1 25mL Sample Dilution Vial, 1000/cs addition, the lot number is laser-etched on each lancet for high puncture speed and complete retraction; (4) Self-
easier tracking. destructive mechanism prevents possibility of reuse; (5)
Gamma sterilized with a twist-and-pull tab for reliable, secure
366592 Lancet, Purple, Blood Volume: Low Flow, 30 G x sterilization protection.
366593 1.5mm depth, 200/bx, 10 bx/cs
366594 Lancet, Pink, Blood Volume: Medium Flow, 21 G x 7045 Lancet, 2.4mm Penetration Depth, Needle 21G,
1.8mm depth, 200/bx, 10 bx/cs Color Coding Green, 200/bx
Lancet, Blue, Blood Volume: High Flow, 1.5mm x
2.0mm depth, 200/bx, 10 bx/cs 7245 Lancet, 2.4mm Penetration Depth, Needle 21G,
Color Coding Green, 100/bx
ARKRAY ASSURE® LANCE LOW FLOW LANCETS BD MICROTAINER®
QUIKHEEL™ LANCET
980125 Low Flow 25G Lancets x 2mm, 100/bx HTL-STREFA MEDLANCE®
980225 Low Flow 25G Lancets x 2mm, 200/bx A safety-engineered product designed PLUS LITE
for heelsticks on babies and neonates.
ARKRAY ASSURE® LANCE PLUS SAFETY LANCETS The simple one-handed activation Collecting blood has never been so
releases a retractable surgical blade for painless! Ideal for blood glucose
990125 Lancet, 25G x 1.1mm, Dark Blue, 100/bx precise, consistent incision. Provides monitoring purposes. Features include:
990130 Lancet, 30G x 0.7mm, Purple, 100/bx sufficient blood flow to conduct low (1) Intuitive two step operation and
trauma sampling. contact activation; (2) Improve patient
comfort with silicone coated needles;
ARKRAY ASSURE® LANCE 368100 QuikHeel Preemie Lancet, Pink, .85mm Incision (3) Increase safety using a double spring mechanism to
SAFETY LANCETS 368101 Depth, 1.75mm Incision Length, 50/bx, 4 bx/cs ensure high puncture speed and complete retraction; (4)
QuikHeel Infant Lancet, Teal, 1.0mm Incision Self-destructive mechanism prevents possibility of reuse; (5)
Used by healthcare professionals Depth, 2.5mm Incision Length, 50/bx, 4 bx/cs Gamma sterilized with a twist-and-pull tab for reliable, secure
to obtain capillary blood samples. sterilization protection.
Designed to help facilities meet OSHA HEMOCUE SAFETY LANCETS
requirements for needlestick safety. 7043 Lancet, 1.5mm Penetration Depth, Needle 25G,
The needle is shielded before and after 130148 Safety Lancet, 2.25mm, 200/bx Color Coding Purple, 200/bx
use. Also features an automatic lockout after use. This system
helps protect healthcare professionals and patients from HTL-STREFA ACTI-LANCE 7243 Lancet, 1.5mm Penetration Depth, Needle 25G,
accidental needle stick injuries and cross-contamination. SAFETY LANCET Color Coding Purple, 100/bx
980121 Lancet, 21G x 1.8mm, Green, 100/bx Put safety and comfort first with Acti- HTL-STREFA MEDLANCE®
980128 Lancet, 28G x 1mm, Light Blue, 100/bx Lance Safety Lancet. Features include: (1) PLUS SPECIAL
980228 Lancet, 28G x 1mm, Light Blue, 200/bx Intuitive two step operation and push button
activation “T” grip for familiar, syringe like Perfect for heel sticks on neonates and
ARKRAY HYPOLANCE™ AST LANCING KIT experience; (2) Improve patient comfort with finger sticks on adults for high flow. Ultra
silicone coated needles and low firing force; sharp blade ensures adequate blood
410012 Kit Contains: HypoLance/ Autolet Impression (3) Increase safety using a double spring volume and quick healing. Features
Lancing Device, Regular & Clear End Cap, mechanism to ensure high puncture speed include: (1) Intuitive two step operation
Instructions For Use, 10 TechLite AST Lancets and complete retraction; (4) Self-destructive and contact activation; (2) Improve
mechanism prevents possibility of reuse; (5) Gamma sterilized patient comfort with silicone coated needles; (3) Increase
ARKRAY MULTI-LANCET DEVICE™ with a twist-and-pull tab for reliable, secure sterilization safety using a double spring mechanism to ensure high
protection. Each unit is single use, with different color-coded puncture speed and complete retraction; (4) Self-destructive
Small, spring-loaded pen device that is versions to provide correct needle exposure length and mechanism prevents possibility of reuse; (5) Gamma sterilized
used with a standard lancet to obtain adequate blood flow. with a twist-and-pull tab for reliable, secure sterilization
a capillary blood sample. It features an protection.
adjustable tip that allows you to choose 7141 Lite, 28G Needle, 1.5mm Depth, Purple, 200/bx
from five settings for maximum comfort. It is compatible with 7142 Universal, 23G Needle, 1.8mm Depth, Blue, 200/bx 7046 Blade 0.8mm, Penetration Depth 2.0mm, Color
most standard lancets. 7143 Special, 17G Blade, 2.0mm Depth, Yellow, 200/bx Coding Yellow, 200/bx
660015 Lancing Device 7155 Lite, 28G Needle, 1.5mm Depth, Purple, 100/bx
7156 Universal, 23G Needle, 1.8mm Depth, Blue, 100/bx 7246 Blade 0.8mm, Penetration Depth 2.0mm, Color
7157 Special, 17G Blade, 2.0mm Depth, Yellow, 100/bx Coding Yellow, 100/bx
Blood Collection Products 175